You can now enjoy that great warmth and a soothing feeling when you get these quality pack of heated car seats. The seats have been equipped with fast heating wires to heat up in minutes. It provides even heating on both the back and seat to beat the cold weather. More interestingly, you can easily control the temperature of the seat to suit your needs.
Additionally, the pack provides you with two comfy heated seats that will fit your car. They are easy to set-up and with a simple plug into the car`s cigarette lighter, they will effectively heat up. Seat Heated Kit,Seat Heater In Cars,Carbon Fiber Seat Heated,Heated Seat For Car JiLin Province Debang Auto Electric Co.,Ltd. , https://www.dbatelectric.com
Failure causes Remedy No pressure or stress after start-up 1, pilot valve in the middle and lower orifice blocked; malfunction cause Method of exclusion No pressure or stress after start up 1, the pilot valve in the middle and lower orifice blocked;
2, unloading valve main valve stuck, or damaged;
3, thrust piston seal ring damage;
4, unloading valve pilot valve stuck, or damaged; 1, to clear the throttle block;
2, check the main valve is stuck or damaged;
3, replace the thrust piston seal;
4, check the pilot valve is stuck or damaged; Pressure pulsation, lack of flow or no flow, and even pipeline vibration, serious noise 1, pumping liquid chamber air is not discharged net;
2, plunger seals, aspirating liquid;
3, suction hose too thin or dead curve;
4, Suction valve spring breakage or spool damage;
5, the suction valve screwed plug is not tightened;
6, liquid suction filter is blocked; 1, Loosen the pump bleed screw, put net weight air;
2, remove the drain valve to fill the plunger cavity;
3, exchange suction pipe or eliminate dead bend;
4, replace the spring or replace the spool;
5, Tighten the suction valve screw plug;
6, cleaning liquid tank suction filter; Plunger seal at a serious leak 1, plunger seal wear or damage;
2, the plunger surface has a serious scratch, nap; 1, replace the seal;
2, replace or repair the plunger; Pump running noise, a percussion sound 1, bush gap increased;
2, pump debris;
3, the motor and pump axis is not coaxial;
4, there is a gap between the plunger and the pressure block; 1, replace the bearing;
2, clear debris;
3, adjust the motor and pump, so that it is coaxial;
4, tighten the compression screw sleeve; Case temperature is too high 1, the oil is dirty or not enough;
2, bush damage or crankshaft hairless; 1, refueling or cleaning the oil pool, oil change;
2, Repair crankshaft and change bearing; Pump pressure suddenly rises above unloading valve setting pressure or safety valve setting pressure 1, the upper or lower pilot valve plugged blocked;
2, the pilot valve regulator screw is misjudged;
3, safety valve failure; 1, to clear the throttle block;
2, re-adjust the pressure;
3, check to adjust or replace the safety valve; Stent stopped feeding unloading valve moves frequently 1, stent system serious liquid leakage;
2, unloading valve check valve leakage;
3, pilot valve leak; 1, to eliminate the leakage area of ​​the face bracket;
2, check the replacement check valve;
3, check pilot valve surface and seal; Emulsion temperature is high 1, the pilot valve sealing ring damage;
2, one-way valve overflow; 1, check the pilot valve o-ring;
2, check the check valve for damage;
2, unloading valve main valve stuck, or damaged;
3, thrust piston seal ring damage;
4, unloading valve pilot valve stuck, or damaged; 1, to clear the throttle block;
2, check the main valve is stuck or damaged;
3, replace the thrust piston seal;
4, check the pilot valve is stuck or damaged; pressure pulsation, lack of flow or no flow, and even pipeline vibration, serious noise 1, the pump chamber air is not discharged net;
2, piston seals, aspirating liquid;
3, suction hose too thin or dead curve;
4, Suction valve spring breakage or spool damage;
5, the suction valve screwed plug is not tightened;
6, liquid suction filter is blocked; 1, loosen the pump bleed screw, put the net air;
2, remove the drain valve to fill the plunger cavity;
3, exchange suction pipe or eliminate dead bend;
4, replace the spring or replace the spool;
5, Tighten the suction valve screw plug;
6, liquid cleaning liquid suction filter; plunger seal leak serious 1, piston seal wear or damage;
2, the plunger surface has a serious scratch, nap; 1, replace the seal;
2, replace or repair the plunger; noise when the pump is running, a percussive sound 1, bearing clearance increased;
2, pump debris;
3, the motor and pump axis is not coaxial;
4, there is a gap between the plunger and the pressure block; 1, replace the bearing;
2, clear debris;
3, adjust the motor and pump, so that it is coaxial;
4, tighten the compression nut; box temperature is too high 1, the oil is dirty or not enough;
2, bush damage or crank hair; 1, refueling or cleaning the oil pool, oil change;
2, repair crankshaft and change the bearing pad; pump pressure suddenly rises above unloading valve setting pressure or safety valve setting pressure 1, the pilot valve above or below the throttle plug is blocked;
2, the pilot valve regulator screw is misjudged;
3, the safety valve failure; 1, to clear the throttling plug;
2, re-adjust the pressure;
3, check to adjust or replace the safety valve; bracket to stop the liquid when unloading valve action 1, the stent system serious liquid leakage;
2, unloading valve check valve leakage;
3, the pilot valve leaks; 1, to eliminate the leakage area face bracket;
2, check the replacement check valve;
3, check pilot valve surface and seal;
Emulsion temperature is high 1, the pilot valve seal damage;
2, one-way valve overflow; 1, check the pilot valve o-ring;
2, check the check valve for damage;