emulsifying homogenizer,Hydraulic lifting high speed disperser,Vacuum high shear paint disperser,Industrial High Speed Disperser,Stainless Steel Liquid Mixing Equipment,planetary dispersion mixer.
Lab High-speed disperser is mainly used in industrial department and scientific research institute for scientific experiment,production simulation and new products R$D in industries such as coating,ink,paint,color paste,pigment,dyestuff,billet and glaze of ceramic,silver aluminum paste etc.
emulsifying homogenizer,Hydraulic lifting high speed disperser,Vacuum high shear paint disperser,Industrial High speed disperser,Stainless Steel Liquid Mixing Equipment,planetary dispersion mixer. Boom Machinery (Changzhou) CO., Ltd , https://www.chileintelligence.com
one. Technical specifications:
Power supply: 538/0V/50Hz 3-phase, dynamic braking device (208V/60Hz optional)
3 saw blade diameter: 500mm
4 cutting depth: up to 200mm
5 cutting length: minimum 450mm
6 gas supply: (fixed test pieces) 700kPamin
7 size: 1900x950x1700mm
8 weight: 300kg
*------------------------------------------------- -------------------------------
Automatic asphalt mixture specimen cutting machine introduction:
two. Detailed introduction:
This preparation system is designed to cut specimens quickly and accurately:
This system has a complete set of linkages to ensure operator safety:
1. When cutting the specimen, the saw blade will automatically advance. After the cutting is completed, the saw blade will automatically return to the initial position.
2. The operator can choose the most suitable cutting speed according to different test pieces and production volume.
3. The prismatic test piece will be fixed by the operator's control pneumatic clamp when cutting. When the cylindrical test piece is cut, it will be fixed by the manual manual clamp. 4. A simple spacer device is installed at the test piece position, and 50* can be cut without measurement. For 62.5mm trabecular specimens, additional trabecular specimen sizes are also applicable.
5. Cylindrical specimen fixtures ensure that specimens are minimally damaged during cutting and that specimens are firmly held during cutting.
6. By using a PVC tube to protect the cylindrical specimen, a more ideal cutting effect can be achieved.
7. It has an electronically controlled pneumatic adjustment specimen position system to ensure that specimen cut length (150mm) and perfectly cut parallel sections.
8. The system can be used for 100mm diameter cylindrical specimens, rapid and accurate cutting specimen length (150mm)
Automatic asphalt mixture tester cutting machine using method
Automatic asphalt mixture tester cutting machine technical parameters: